WE Report

Lessons Learned

Lesson Learned





No user selected

Report No.

194

Discipline/Origin

Drilling
No origin

Well

Kallåsen
35/12-6 S

Date created

2019/02/05
2497 days ago

Project Phase

Operational
Project Phase

LL Type/Classification

Equipment
Negative

Transocean Arctic


What happened in Surface section:
The stop ring for balloon centralizer on the inner string cmt stinger was installed on top of centralizer. This was wrong, and we were not able to get centralizer through the 18 ¾” WH. POOH and installed stop ring inside centralizer. This allow centralizer to “stretch out” and enter WH.

What Was Planned

Run balloon centralizer on innerstring cement stinger

What Was Learned

Centralizers on casing have stop ring above and below centralizers, but these are more rigid and of different type. For DP type “balloon centralizer”, stop ring should always be installed in middle.

What Actions Are Required

Always install stop ring in middle for “balloon centralizer”.

EDITOR


CLOSE LL (testing)





New Lesson Learned

You do not have permission to view this form.




\n\t\t

\n\t\t\t\n\t\t\t