WE Report

Lessons Learned

Lesson Learned





By: Drilling Engineer

Report No.

1970

Discipline/Origin

Drilling
No origin

Well

Oselvar
A-3 HT2

Date created

2021/07/05
1616 days ago

Project Phase

Operational
Project Phase

LL Type/Classification

Equipment
Negative

Borgland Dolphin


What happened in P&A:
The 9 5/8″ casing hanger had a 10″ pup joint made up to it This was not identified on the hanger schematic. The 10″ could not be handled with the rig or franks elevators and could not be broken out with the franks tong. The assembly needed to be layed down as a 19 m long piece which was awkward and time consuming.

What Was Planned

The plan was to use 9 5/8″ inserts on the iron roughneck.

What Was Learned

Old tallies are not always 100% correct.

What Actions Are Required

For wells A-2 and A-1 it is recommended to get 10″ elevator inserts and casing jaws.