WE Report

Lessons Learned

Lesson Learned





By: Lene Lomeland

Report No.

6803

Discipline/Origin

Drilling
No origin

Well

Falstaff
2/6-7 S

Date created

2024/10/07
425 days ago

Project Phase

Operational
Project Phase

LL Type/Classification

Equipment
Negative

What happened in Top hole:
Discovered dimensional issue between FA-1 tool and Dril-Quip couplings. Unable to enter with FA-1 tool into box end of float collar joint. FA-1 Guide Cone OD = 18.55”, FA-1 Packer Cup OD = 18.98” and Float Collar joint box ID = 18.25”.

What Was Planned

Run the 20” casing with FA-1 tool. This allows for washing the casing down if any hole problems encountered.

What Was Learned

Verify compatibility prior to shipment offshore.

What Actions Are Required

Make all efforts to ensure casing coupling ID is always equal or greater to pipe ID (this is a planning issue, subject to final verification offshore).