WE Report

Lessons Learned

Lesson Learned





By: Sander Schaathun

Report No.

8483

Discipline/Origin

HSEQ
No origin

Well

Kjøttkake
35/10-13

Date created

2025/03/24
257 days ago

Project Phase

Operational
Project Phase

LL Type/Classification

Equipment
Negative

Deepsea Yantai


What happened in P&A:
When cementer was dropping/pushing CST into DP filled with OBM “splashed” out of pipe and spilled on cementers face.

What Was Planned

Running CST

What Was Learned

Mud in pipe must be removed before trying to force anything in the pipe, as the CST or any other object displace the mud, the mud must go somewhere, and it will spill where cementers are standing.

What Actions Are Required

Either pump slug prior to installing CST or remove mud with vacum.
Should implement to run slug prior to installing in future DOP’s.

What Was Done

Added in ‘As Done’ DOP.