What happened in P&A:
In DOP for pulling 9 5/8″ seal assembly, it was planned “Pick up with 3 ton overpull to check MPT engaged in seal assembly.” This was planned to do prior to closing annular. DQ engineer stated that this has been enough on other wells to pull seal assembly free with gas pressure below.

What Was Planned

Pull and retrieve the 9 5/8″ seal assembly

What Was Learned

3 ton overpull has been enough on other wells to pull seal assembly free with gas pressure below.

What Actions Are Required

Always close annular prior to pull on seal assembly, regardless the pull force.