Lesson Learned





By: Drilling Engineer

Report No.

5858

Discipline/Origin

Drilling
Own Experience

Well

Norma
25/7-11 S

Date created

2023/07/30
860 days ago

Project Phase

Operational
Project Phase

LL Type/Classification

Equipment
Negative

Deepsea Yantai


What happened in Top hole:
Due to problems with cement around the conductor and movement in conductor a Bullseye bracket from DQ was sent out but not installed.

What Was Planned

No inclinometer was planned. Only planned for measuring the inclination of the WH with the bullseye on the WHRT.

What Was Learned

The bullseye bracket not suitable to install subsea.

What Actions Are Required

If WH already installed without an installed tool for measuring inclination, evaluate to use a three-leg WH inclinometer from Oceaneering that can be installed subsea.