What happened in Intermediate section:
The 17 1/2″ section was drilled, but it proved difficult to get hold of Glycol for the KCl mud.

What Was Planned

A contingency 17 1/2″ BHA and 13 3/8″ contingency casing was planned for.

What Was Learned

Ensure contingency mud is planned for the contingency sections. Including sufficient pre-mix if having to drill with low mud weight.

What Actions Are Required

Ensure contingency mud is planned for the contingency sections. Including sufficient pre-mix if having to drill with low mud weight.