WE Report

Lessons Learned

Lesson Learned





By: Drilling Engineer

Report No.

5840

Discipline/Origin

Drilling
No origin

Well

Carmen
35/10-10S

Date created

2023/06/20
901 days ago

Project Phase

Planning
Project Phase

LL Type/Classification

Casing
N/A

Deepsea Yantai


What happened in Intermediate section:
It was run according to tally.

What Was Planned

The 9 7/8″ Casing was planned with two different connections. Needed XO from Vam 21 and Vam Top and a XO for the hgr. The Primary and BU XO sent out was 6 m different in length

What Was Learned

To have the BU XO the same length as the Primary. If one of the XO needs to be changes out running casing the casing string would suddenly be 6 m longer due to BU being 6 m longer.

What Actions Are Required

Send out BU XO same length as Primary