WE Report

Lessons Learned

Lesson Learned





By: Sturla Jensen

Report No.

1418

Discipline/Origin

Subsea
Own Experience

Well

Oselvar
A-1 H, A-2 H, A-3 HT2

Date created

2021/04/10
1701 days ago

Project Phase

Operational
Project Phase

LL Type/Classification

No classification

Borgland Dolphin


What happened in P&A:
Disconnected BOP.
Inspected top of TH and crown plug.

What Was Planned

Pull BOP to check for debris in WH HXT. Top of TH and Crown plugs. This decision was made due to the damage we had on SSTT when POOH and to check for junk. Possible rubber bits from annular could have fallen into well.

What Was Learned

Found the WH, TH cavity full of debris. See Pictures. No big junk was found. No rubber parts from the annular were found. Only light debris from the Marine riser or BOP was found. Looked like dark find sand. The assumption is that this debris has been caused by the long time SSTT lading string was riding up and down in the marine riser WOW.

What Actions Are Required

Flushed the WH and TH cavity area clean with ROV jetting hose.

What Was Done

Pull BOP to check for debris in WH HXT.
Inspected top of TH and crown plug.
Found the WH, TH cavity full of debris.
Flushed the WH and TH cavity area clean with ROV jetting hose.